ARMY TM 9-6115-670-14&P
4-77
4.32. FUEL DAY TANK ASSEMBLY (JTACS and WIN-T).
This task covers:
a. Service
b. Test
c. Repair
d. Replace
INITIAL SETUP
Tools
Shop Equipment, Electrical Repair,
Semi trailer Mounted
(Item 3, Appendix B)
Hand Siphon
(Item 22, Appendix B)
Gloves, Chemical Oil Protective
(Item 34, Appendix B)
Equipment Conditions
Engine stopped and allowed to cool completely.
MASTER ON-OFF switch on APU control unit set to
OFF.
Materials/Parts
Low-level Cut-off Switch
Sealing Compound 88-20595-2
(Item 18, Appendix F)
Approved Solvent
SERVICE
WARNING
Ensure that NO IGNITION SOURCE is within 50 feet
of the 10 kW APU. The fuel in this APU is highly
flammable. Do not smoke. Do not splash fuel on hot
components. Failure to heed this warning could
result in serious injuries to personnel or DEATH.
WARNING
Avoid fuel contact with skin. Wear protective gloves,
goggles, apron and mask, while disconnecting fuel
lines. Failure to heed this warning could result in
serious injuries to personnel or DEATH.
NOTE
When disconnecting fuel lines, use a suitable
container to catch fuel from disconnected fuel lines.
CAUTION
Take care not to cut wires or other APU components
when removing tiedown straps.
NOTE
Cut and remove tiedown straps as needed to remove
wiring harness.