TM 9-6115-669-13&P
REMOVAL
a.
b.
C.
d.
e.
f.
g
h.
N O T E
This procedure is the same for all one-phase PDU Power Cables.
Remove stanchion by PDU (1, figure 5-6).
Open access door (2) and secure with prop (3).
Install stanchion.
Remove screws (4), serrated lock washer (5), washer (6), and protective cover (7).
Remove screw (8), serrated lock washer (9), washer (10), and cables (11,12) from appropriate
bus bar (15).
Cut cable ties from cable bundles.
Using the shop manufactured wrench, remove nut (13) from appropriate corrugated hose (14),
and remove from cables (11,12).
Remove corrugated hose (14) and cables (11,121 from PDU (1).
INSPECTION
a. Check that cable is in good external condition.
b.
Check that protective covers, lanyards and cable ties (16, 17, and 18, figure 5-7) are in good
condition. Replace if damaged.
TEST
Using a high voltage tester:
a. Test voltage: 1000 V for 1 minute between wire and ground. The tester must not activate.
b.
Use multimeter to test for continuity.
REPAIR
a.
Remove lugs (11, figure 5-7) from cables (9, 10).
b.
Using two wrenches, unscrew locked screw connection (1).
c.
Grasp connector and pull cables (9,10) and parts (5 to 8) and (12, 13) out of corrugated hose
(15). Assembled parts (2 to 4) then fall from corrugated hose (14).
N O T E
Do not disassemble components (2 to 4) unless one of the components is damaged.
Change 1
5-11