TM 9-6115-669-13&P
a
Perform steps a. through f. as described in Removal Using a Crane.
WARNING
For safety reasons (load imbalance) always we the forklift on
the side of the pallet frame where the cable drums are located
CAUTION
Use only forklifts with a fork length of at least 80 inches (2000 mm) and a
capacity of approximately 12,000 lb. (6 metric tons). Place a mark at 20
inches (5000 mm) as shown in figure 4-24.
b.
Fold down side panels (2, figure 4-23).
WARNING
Use the forklift only on the side of the Generator Set 150 kW as
shown in figure 4-24.
c.
Position the forklift in front of the Generator Set 150 kW and insert the forks into the forklift
sockets (1, figure 4-23) as far as possible. The remaining fork length visible will then be
approximately 20 inches (500 mm).
CAUTION
Do not damage PDU cable (10, figure 422) during lifting of the Generator
Set 150 kW.
d.
Lift the Generator Set 150 kW and place it on a solid surface.
4-51