4-34.
NATO RECEPTACLE MAINTENANCE
7.
Tag ground electrical lug (12). Remove NATO receptacle (5) from fuel module by removing screws (13) and nuts
(14). Remove gasket (15).
B.
INSPECTION.
1.
Inspect electrical wiring for cuts, abrasions, and bare wire. Check wiring insulation for damage.
2.
Inspect NATO receptacle for corrosion or other obvious damage. Check for evidence of electrical short.
3.
Inspect NATO receptacle for bent, broken, missing, or corroded electrical contactors. Ensure all components are
securely fastened.
4.
Inspect receptacle gasket for cuts, tears, deformation, deterioration, or permanent set. Replace as required.
C.
INSTALLATION.
1.
Install NATO receptacle (5, Figure 4-24) and gasket (15) into fuel module using screws (13) and nuts (14). Ground
electrical lug (12) is secured by the lower left hand screw and nut.
2.
Connect positive electrical wires (8, 9) to NATO receptacle (5) using bolt (10) and lockwasher (11).
3.
Connect negative electrical wire (4) to NATO receptacle (5) using bolt (6) and lockwasher (7).
4.
If removed, install cover latches (3) and locking screws.
5.
Mate fuel module cover (1) to enclosure (2). Lock in place by engaging cover latches (3).
6.
Close top rear cover and lock using latches.
4-87