TM 9-6115-664-13&P
4-33.
FLOAT VALVE HOUSING ASSEMBLY MAINTENANCE
F.
INSTALLATION.
1.
Install thread sealant on threads of elbows (11, 15,
Figure 4-23) and adapter (20) that install into float
valve housing assembly (37). Install elbows and
adapter. Refer to figure for correct orientation of
elbows.
2.
Install housing assembly (37) using screws (36),
locknuts (21), and washers (22).
3.
Connect fuel hose (13) to elbow (11).
4.
Connect fuel hose (14) to elbow (15).
5.
Install elbow (18) into adapter (20). Connect fuel
hose (17) to elbow.
6.
Install fuel module front plate (1) onto enclosure (2)
using four screws (3), lockwashers (4), washers (5),
and two screws (6).
7.
Connect two fuel hoses (10) to rear of bulkhead
fittings (7).
8.
Connect electrical cables to rear of feed-thru studs
(9) and secure using stud nuts and washers.
9.
Install electrical connector (8) into hole in front plate
(1).
10. Install fuel module assembly (Task 4-30).
Figure 4-23. Float Valve Housing
(Sheet 4 of 4)