4-35.
ELECTRICAL CONTACTOR MAINTENANCE
C.
INSTALLATION.
1.
Apply silicon adhesive to back mounting surface of
rain guard plate (26, Figure 4-25). Install electrical
contactor (22) and plate onto fuel module using
screws (23), washers (24), and locknuts (25).
2.
Connect electrical wires (17, 18) to electrical
contactor (22) using nuts (19), lockwashers (20), and
washers (21). Wire (17) is installed on the left
contactor stud, wire (18) on the right stud.
3.
Connect electrical wires (10, 11, 12, 13) to contactor
(22) using nuts (14), lockwashers (15), and washers
(16). Wires (10, 12) are installed on the left
contactor stud, wires (11, 13) on the right stud.
4.
Install fuel module front plate (1) onto enclosure (2)
using four screws (3), lockwashers (4), washers (5),
and two screws (6).
5.
Connect two fuel hoses (10) to rear of bulkhead
fittings (7).
6.
Connect electrical cables to rear of feed-thru studs
(9) and secure using stud nuts and washers.
7.
Install electrical connector (8) into hole in front plate
(1).
8.
Install fuel module assembly (Task 4-30).
Figure 4-25. Electrical Contactor
4-89