TM 9-6115-647-14&P
(2)
Connect wires and two jumpers (2) to terminal board (1). One jumper must link terminals 1
and 2 and the second jumper must link terminals 2 and 3. When reconnecting wires, refer to
the PDU wiring diagram, figure 4-11, or to the schematic located inside the PDU cover.
(3)
Close and latch PDU cover.
Figure 5-9. PDU Terminal Board Replacement.
Section IV. FUEL SYSTEM MAINTENANCE
5-12. Fuel Tank and Fuel Line Replacement. (See figure 5-10)
a
Removal.
NOTE
If fuel line is being removed but not fuel tank, perform steps (1) through (3)
only.
(1)
Open drain cock (1, figure 5-10) and drain fuel from fuel tank (2) into a container.
(2)
Remove generator set (paragraph 5-2).
(3)
Remove three screws (3), three lockwashers (4) and three loop clamps (5) attaching fuel line
(6) to front and middle-front generator set supports . Loosen fitting (8) on fuel line and
disconnect fuel line from fuel tank . Pull fuel line out of curbside walkway (9).
(4)
Remove front and middle-front generator set supports (7) (paragraph 5-16).
(5)
Unplug P4, P7 fuel cable (10) from fuel level sensor (11) on fuel tank (2).
5-18