ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARINE CORPS TM 09244A/09245A-24/2
d.
Connect pins 1 and 2 of fuel float module electrical connector (J12) together with a jumper wire.
e.
Move MASTER SWITCH to PRIME & RUN AUX FUEL position and auxiliary fuel pump should start operating.
Remove jumper wire and auxiliary fuel pump should stop operating.
f.
Start and operate generator set at rated voltage and frequency.
g.
Using jumper wire, make connection between pins 3 and 4 of fuel float module electrical connector (J12).
Generator set should shut down after approximately 2 seconds and NO FUEL lamp on malfunction indicator
panel should light.
h.
Replace fuel float module if operation is other than above.
i.
Close right side engine access doors.
2-92.3
Removal.
a.
Shut down generator set.
b.
Open battery access door and disconnect negative battery cable.
c.
Open night side engine access doors, tag and connect electrical connectors from fuel float module (51,
FIGURE 2-26).
d.
Remove bolts (49), nuts (50), and fuel float module (51) from generator set.
2-92.4
Installation.
a.
Install fuel float module (51, FIGURE 2-26) in generator set with bolts (49) and nuts (50).
b.
Connect electrical connectors, remove tags, and dose right side engine access doors.
c.
Connect negative battery cable and dose battery access door.
2-93
FUFL FILTFRIDRAIN VALVF ASSFMBI Y.
2-93.1
Removal.
a.
Remove damp (66, FIGURE 2-26) and hose (67) from drain valve assembly.
b.
Remove bolt (60), washers (69), and adapter (70). Discard washers (70).
c.
Remove valve (71) from adapter (70).
2-93.2
Inspection. Check valve assembly for defects and proper operation.
2-93.3
Installation.
a.
Replace adapter (70) on valve (71).
b.
Install new washers (69) and bolt (68) to adapter (70) and tighten to bottom of fuel filter/water separator.
c.
Install hose (61) and damp (60) to drain valve (59).
2-94
ETHER CYLINDER.
2-94.1
Removal.
a.
Shut down generator set.
b.
Open right side engine access doors.
c.
Loosen wing nut (1., FIGURE 2-27) and unscrew ether cylinder (2.) from ether solenoid valve (9.).
d.
Install cap (3.) in solenoid valve (9.).
e.
Remove bolts (4.), lockwashers (5.), washers (6.), and ether cylinder bracket assembly (7.) from generator
set housing.
Change 3 2-127