ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARINE CORPS TM 09244A/09245A-24/2
2-91 FUEL PICKUP.
2-91.1
a.
b.
c.
d.
e.
f.
2-91.2
a.
b.
c.
d.
e.
2-91.3
a.
b.
c.
d.
e.
f.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Open left side engine access doors and disconnect fuel line (42, FIGURE 2-26) from fitting (48).
NOTE
Mark position of fuel pickup before removing.
Remove screws (43), Iockwasher (44), flatwashers (45), fuel pickup (46), and gasket (47) from fuel tank.
Remove fitting (48) from fuel pickup (46).
Cover opening in fuel tank.
Inspection.
Shut down generator set.
Remove fuel pickup, paragraph 2-91.1.
Inspect fuel pickup and fitting for clogs, stripped threads, and other damage.
Replace damaged parts.
Install fuel pickup, paragraph 2-91.3.
NOTE
Ensure fuel pickup is in same position as marked on removal.
Remove cover in fuel tank opening.
Thoroughly clean mating surfaces for new gasket (47, FIGURE 2-26). Ensure no foreign materials enter fuel
tank. Apply sealant (item 21, Appendix C) to both sides of gasket (47).
Install gasket (47, FIGURE 2-26) and fuel pickup (46) in fuel tank with screws (43), Iockwashers (44), and flat-
washers (45).
Install fitting (48) in fuel pickup (46).
Connect fuel line (42) to fitting (48) and close left side engine access doors.
Connect negative battery cable and close battery access door.
2-92 FUEL FLOAT MODULE.
2-92.1
a.
b.
c.
d.
2-92.2
a.
b.
c.
Inspection.
Shut down generator set.
Open right side engine access doors.
Inspect fuel float module (51, FIGURE 2-26) for cracked housing, broken or damaged connectors and wiring,
and other damage.
Close engine access doors.
Testing.
Shut down generator set.
Open right side engine access doors.
Disconnect fuel float module (51, FIGURE 2-26) electrical connector (J12) from fuel float switch connector (P12).
2-126