NOTES:
PROCEDURES:
2. Refer to TM 9-6115-644-24P for materials
1. Dimensions shown are in inches.
required.
1. Cut wire (1) to length indicated.
2. Strip 0.75 inch of insulation sleeving from each end
of wire (1).
3. Mark insulation sleeving (2) with wire number
165B0, position on center of wire and shrink to fit.
4. Mark insulation sleeving (4) with POSITIVE and
slide over each end of wire (1).
5. Crimp terminal (3) on each end of wire (1).
6. Position insulation sleeving (4) as shown and shrink
to fit.
FIGURE D-4. Cable Assembly, Battery (P/N: 88-22181)