ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
NOTES:
PROCEDURES:
1. Dimensions shown are in inches.
1. Cut rope (1) to length indicated.
2. Refer to TM 9-6115-644-24P for materials
2. Slide insulation sleeving (2) over one end of rope
required.
(1).
3. Crimp terminal (3) on each end of rope (1).
4. Install hook (4) in one terminal (3) and close
hook end securing it to terminal.
5. Position insulation sleeving (2) as shown and
shrink to fit.
FIGURE D-7. Holder, Control Panel (P/N: 88-22120)
D-7