NOTES:
ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
1. Dimensions shown are in inches.
2. Refer toTM9-6115-644-24P for materials
required.
PROCEDURES:
1.
2.
3.
4.
5.
6.
Cut wire (1) to length indicated.
Strip 0.75 inch of insulation from each end
of wire (1).
Position insulation sleeving (2) on center
of wire, mark with wire number 100A0
and shrink to fit.
Mark insulation sleeving (4) with
NEGATIVE and slide over one end of
wire (1).
Crimp terminal (3) on each end of wire (1).
Position insulation sleeving (4) as shown
and shrink to fit.
FIGURE D-3. Cable Assembly, Battery (P/N: 88-22127)
D -3