ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
c.
d.
e.
f.
2-1-2-3.
Table 2-1. Coolant
AMBlENT TEMPERATURE
RADIATOR COOLANT
RATIO
+40°F TO +120°F
WATER: MIL-A-53009
35:1
(4°C TO 49°C)
INHIBITOR, CORROSION
-25°F TO +120°F
WATER: MIL-A-46153
1:1
(-31°C TO 49°C)
ANTIFREEZE
-25°F TO +120°F
MIL-A-11755
N/A
(-31°C TO 49°C)
ANTIFREEZE
Fill radiator with proper coolant/antifreeze in accordance with Table 2-1. Fill radiator to a level two inches below
filler neck opening. Cooling system capacity is 6.2 quarts (5.9 liters). Install radiator cap.
Remove overflow bottle cap.
Fill overflow bottle to COLD level and install overflow bottle cap.
Start generator set. After 30 minutes of operation, shutdown generator set and check coolant/antifreeze level
at overflow bottle. Add coolant/antifreeze in accordance with Table 2-1, to HOT level in overflow bottle.
Fuel Tank.
Maintain metal-to-metal contact between fuel tank filler neck and fuel nozzle to
prevent sparks from static electricity. Do not smoke or use open frame in area of
fueling operation. Failure to follow this warning could result in explosion, severe
personal injury or death.
Table 2-2. Diesel Fuel
AMBlENT TEMPERATURE
DIESEL FUEL
+20°F TO +120°F
VV-F-800 GRADE DF-2,
(-7°C TO 49°C)
JP4, JP5, OR JP8
0°F TO +20°F
VV-F-800 GRADE DF-1,
(-17°C TO -7°C)
JP4, JP5, OR JP8
-25°F TO 0°F
VV-F-800 GRADE DF-1
(-31°C TO -17°C)
-25°F TO 0°F
VV-F-800 GRADE DF-A
(-31°C TO -17°C)
2-2