ARMY TM 9-6115-641-10
AIR FORCE TO 35C2-3-456-11
Table 1-1. Leading Particulars - Continued
7.
AC Generator - Continued:
MEP-802A
MEP-812A
Type
Rotating
Rotating
field
field
synchronous
synchronous
Load Capacity
5kW
5kW
Current Ratings:
60 Hz:
400 Hz:
120/240 volt connection
26 amps
26 amps
120/208 volt connection
17 amps
17 amps
120 volt connection
52 amps
52 amps
Power Factor
0.8
0.8
Cooing
Fan cooled
Fan cooled
Drive Type
direct
direct
coupling
coupling
Duty Classification
continuous
continuous
8. Protection Devices:
Low Oil Pressure Switch:
Trip Pressure
15 ± 3 psi (103.4 ± 20.7 kPa)
Voltage Rating
24 VDC
Current Rating
5 amps
Coolant High Temperature Switch:
Trip Temperature
225 ± 5° F (107 + 3°C)
Voltage Rating
12-120 VDC
Current Rating
2 amps
Overvoltage:
Trip Point Conditions
153 ± 3 VAC for
no less than 200
milliseconds (120
VAC coil winding)
Trip Point
No more than 1.25
seconds after trip
conditions exist
1-10