ARMY TM 9-6115-641-10
AIR FORCE TO 35C2-3-456-11
fuel supply to the generator fuel tank The fuel level float
switch shuts off the auxiliary fuel pump when the
generator fuel tank is full and reactivates the pump as the
level drops. The FUEL LEVEL indicator indicates fuel
level of generator fuel tank from (E) empty to (F) full in
quarter tank increments.
1-13
1-13.1
The Engine Cooling System (FIGURE 1-5)
consists of a radiator, hoses, thermostat, water pump, a
belt driven fan, and cooling jackets. The water pump
forces coolant through passages (cooling jackets) in the
engine block and cylinder head where the coolant absorbs
heat from the engine. When the engine reaches normal
operating temperature, the thermostat opens and the
heated coolant flows through the upper radiator hose
assembly into the radiator. The cooling fan circulates air
through the radiator where the coolant temperature is
reduced.
1-13.2
A coolant high temperature switch provides
automatic shut dovvn in the event that coolant temperature
exceeds 225 ± 5°F (107 ± 3°C). The COOLANT TEMP
indicator indicates the engine coolant temperature, from
120°F to 240°F (48°C to 115°C).
Figure 1-5. Engine Cooling System
Change 1 1-13