Figure 5-2.
TM 5-6115-625-14&P
5-4. Marking. (See figure 5-2.) The power unit four-digit registration number, preceded by the
prefix VD and the words U.S. ARMY, is marked in three places on the trailer. Marking is done in
accordance with MIL-STD-642. On the fender, over each wheel, T.P. 35 PSI is marked in 1.00 ±
.12 inch high characters in accordance with MIL-STD-130. Figure 5-2 shows the approximate
location of markings on the power unit. If required, touch-up painting of the base color shall be done
in accordance with MIL-T-704, Type F, Color Green, No. 383 of MIL-C-46168.
5-5.
a.
Generator Set
Removal.
Replacement.
Section Ill. GENERATOR SET
(See figures 5-3 and 5-4.)
(1) Disconnect ground wire (1, figure 5-3) from generator set (2) to GROUND TERMINAL stud
(3) on trailer.
N O TE
Two center mounting screws on each side can be reached through cutouts in
trailer frame under each fender.
The beveled washers (5) may have been welded in place.
(2) Remove eight screws (4), eight beveled washers (5), eight flat washers (6) and eight
nuts (7) securing generator set (2) to trailer.
5 - 2