TM 9-6150-226-13
5-13 ENCLOSURE ASSEMBLY.
This task covers:
Replacement
INITIAL SETUP
Tools
General Mechanics Tool Kit
SC 5180-90-CL-N26
General Safety Instructions
WARNING
High voltage is present in this
system.
DISE and PDISE supports
equipment using 120/208 V ac. Do
not replace a connector assembly
with the power on.
Death or
serious injury may result.
REPLACEMENT
1.
REMOVE INTERNAL COMPONENTS.
a.
Refer to paragraph 4-17 (para 4-23 for universal adapter) and remove
bus bars and circuit breaker assembly (mounting board and load
terminal).
b.
Refer to paragraph 4-15 (para 4-21 for universal adapter) and remove
all connectors.
c.
Replace enclosure assembly.
2.
INSTALL INTERNAL COMPONENTS.
NOTE
Refer to Figures 4-1 thru 4-11 (Fig. 4-7 for
universal
adapter)
and paragraph
4-10d when
connecting internal wiring.
a.
Refer to paragraph 4-15 (para 4-21 for universal adapter) and install
all connectors.
b.
Refer to paragraph 4-17 (para 4-23 for universal adapter) and install
bus bars and circuit breaker assembly.
5-29/(5-30 blank)