TM 9-6115-730-24
0043
TEST
1. Using multimeter, measure resistance of the resistors. R1 = 150 ohms +/- 1%, R2 = 10 ohms +/- 1%, and R3
= 15 kohms +/1%.
3. Replace any components that fail a measurement test.
END OF TASK
ASSEMBLY
1. Install terminal board (Figure 1, Item 15), two screws (Figure 1, Item 14), and two nuts (Figure 1, Item 13).
2. Install diode CRFF (Figure 1, Item 12).
3. Install resistors R3 (Figure 1, Item 11), R2 (Figure 1, Item 10), and R1 (Figure 1, Item 9), with six screws
(Figure 1, Item 8) and nuts (Figure 1, Item 7).
4. Install DC CONTROL POWER circuit breaker CB1 (Figure 1, Item 6), washer (Figure 1, Item 5), and nut
(Figure 1, Item 4).
5. Install ISOCHRONOUS DROOP switch IDS (Figure 1, Item 3), washer (Figure 1, Item 2), and nut (Figure 1,
Item 1).
7. Remove tags and connect wires to resistor assembly A7 components.
END OF TASK
END OF WORK PACKAGE
0043-3/4 blank