TM 9-6115-730-24
0005
Malfunction/Symptom
Troubleshooting Procedure
GSC FAULT CODE - Continued
23.
CID 174 FMI 03 Fuel Temperature Sensor Voltage Above Normal ................................................... WP 0009
24.
CID 190 FMI 02 Loss of Engine Speed Signal, Erratic, Intermittent, or Incorrect
Signal ........................................................................................................................................... WP 0009
CID 190 FMI 03 Magnetic Pickup Unit (Engine Speed Sensor) Voltage Above Normal.................... WP 0009
25.
CID 190 E FMI 02 Loss of Engine Timing Signal, Erratic, Intermittent, or Incorrect
Signal............................................................................................................................................ WP 0009
CID 190 E FMI 11 Crankshaft (Bottom) Engine Timing Sensor Failure Mode is Not Identifiable
(Mechanical Failure) ........................................................................................................................... WP 0009
26.
CID 248 FMI 09 CAT Data Link Abnormal update ............................................................................. WP 0009
27.
CID 253 E FMI 02 Personality Module Mismatch Erratic, Intermittent, or Incorrect Signal................ WP 0009
28.
CID 254 E FMI 12 ECM Self Test Failed Component ........................................................................ WP 0009
29.
CID 261 E FMI 13 Engine Timing Calibration Device is Not Calibrated............................................. WP 0009
30.
CID 262 E FMI 03 5 V Sensor Power Supply Voltage Above Normal................................................ WP 0009
CID 262 E FMI 04 5 V Sensor Power Supply Voltage Below Normal ................................................ WP 0009
31.
CID 264 E FMI 03 E-Stop Shutdown Voltage Above Normal (Active) ............................................... WP 0009
32.
CID 268 FMI 02 GSC Electronic Control Erratic, Intermittent, or Incorrect Signal ............................. WP 0009
33.
CID 269 FMI 03 GSC 8V Sensor Power Supply Voltage Above Normal ........................................... WP 0009
CID 269 FMI 04 GSC 8V Sensor Power Supply Voltage Below Normal............................................ WP 0009
34.
CID 273 FMI 03 Turbo Outlet Pressure Sensor Voltage Above Normal ............................................ WP 0009
CID 273 FMI 04 Turbo Outlet Pressure Sensor Voltage Below Normal............................................. WP 0009
35.
CID 274 FMI 02 Atmospheric Pressure Sensor Erratic, Intermittent, or Incorrect Signal .................. WP 0009
36.
CID 274 FMI 03 Atmospheric Pressure Sensor Voltage Above Normal ............................................ WP 0009
CID 274 FMI 04 Atmospheric Pressure Sensor Voltage Below Normal............................................. WP 0009
37.
CID 334 FMI 02 Spare Output (P7-36) Erratic, Intermittent, or Incorrect Signal ................................ WP 0009
CID 334 FMI 03 Spare Output (P7-36) Voltage Above Normal.......................................................... WP 0009
CID 334 FMI 04 Spare Output (P7-36) Voltage Below Normal .......................................................... WP 0009
38.
CID 336 E FMI 02 ENGINE CONTROL Switch (ECS) Erratic, Intermittent, or Incorrect Signal ........ WP 0009
39.
CID 342 E FMI 02 Camshaft (Top) Engine Speed/Timing Sensor Erratic, Intermittent,
or Incorrect Signal (Logged) ............................................................................................................... WP 0009
CID 342 E FMI 11 Camshaft (Top) Engine Speed/Timing Sensor Failure mode is not
identifiable (Mechanical Failure) (Logged) ......................................................................................... WP 0009
40.
CID 360 E FMI 01 Low Engine Oil Pressure Warning (Active & Logged) Data is Valid But
Data is Below Normal Operating Range............................................................................................. WP 0009
CID 360 E FMI 02 Low Engine Oil Pressure Derate (Active & Logged) Erratic, Intermittent,
or Incorrect Signal............................................................................................................................... WP 0009
CID 360 E FMI 03 Low Engine Oil Pressure Shutdown (Active & Logged)
Voltage Above Normal ........................................................................................................................ WP 0009
41.
CID 361 E FMI 01 High Engine Coolant Temperature Warning (Active & Logged)
Data is Valid But Data is Below Normal Operating Range ................................................................. WP 0009
CID 361 E FMI 02 High Engine Coolant Temperature Derate (Active and Logged)
Erratic, Intermittent, or Incorrect Signal .............................................................................................. WP 0009
CID 361 E FMI 03 High Engine Coolant Temperature Shutdown (Active & Logged)
Voltage Above Normal ........................................................................................................................ WP 0009
0005-3