REMOVAL - Continued
15. Remove screw (Figure 1, Sheet 2, Item 29), lockwasher (Figure 1, Sheet 2, Item 30), washer (Figure 1,
Sheet 2, Item 31), clamp (Figure 1, Sheet 2, Item 32), and flexible braided leak-off hose (Figure 1, Sheet 2,
Item 28).
16. Remove two hose clamps (Figure 1, Sheet 2, Item 33) and disconnect flexible exhaust tubing (Figure 1,
Sheet 2, Item 34) from heater (Figure 1, Sheet 2, Item 10) and from heater exhaust adapter (Figure 1, Sheet 2,
Item 35).
17. Remove four screws (Figure 1, Sheet 2, Item 36), lockwashers (Figure 1, Sheet 2, Item 37), washers (Figure 1,
Sheet 2, Item 38), and heater exhaust adapter (Figure 1, Sheet 2, Item 35) from skid base.
18. Remove shutoff valve (Figure 1, Sheet 1, Item 2), adapter (Figure 1, Sheet 1, Item 39), and elbow (Figure 1,
Sheet 1, Item 40). Repeat for other shutoff valve (Figure 1, Sheet 1, Item 1).
END OF TASK
INSTALLATION
NOTE
Apply sealing compound to all male pipe threads before connecting.
1. Install elbow (Figure 1, Sheet 1, Item 40), adapter (Figure 1, Sheet 1, Item 39), and shutoff valve (Figure 1,
Sheet 1, Item 2). Repeat for other shutoff valve (Figure 1, Sheet 1, Item 1).
2. Install heater exhaust adapter (Figure 1, Sheet 2, Item 35) on skid base and secure with four washers (Figure
1, Sheet 2, Item 38), lockwashers (Figure 1, Sheet 2, Item 37), and screws (Figure 1, Sheet 2, Item 36).
3. Connect flexible exhaust tubing (Figure 1, Sheet 2, Item 34) to heater exhaust adapter (Figure 1, Sheet 2,
Item 35) and to heater (Figure 1, Sheet 2, Item 10) and install two hose clamps (Figure 1, Sheet 2, Item 33).
4. Install flexible braided leak-off hose (Figure 1, Sheet 2, Item 28), hose clamp (Figure 1, Sheet 2, Item 32),
washer (Figure 1, Sheet 2, Item 31), lockwasher (Figure 1, Sheet 2, Item 30), and screw (Figure 1, Sheet 2,
Item 29).
5. Connect flexible braided leak-off hose (Figure 1, Sheet 2, Item 28) to OUT side of fuel metering pump (Figure
1, Sheet 2, Item 24) and to bottom of heater (Figure 1, Sheet 2, Item 10) and install two hose clamps (Figure 1,
Sheet 2, Item 27).
6. Connect low-pressure hose (Figure 1, Sheet 1, Item 23) to male hose barb fitting (Figure 1, Sheet 1, Item 26)
on left side of fuel tank and install hose clamp (Figure 1, Sheet 1, Item 25).
7. Connect low-pressure hose (Figure 1, Sheet 1, Item 23) to IN side of fuel metering pump (Figure 1, Sheet 2,
Item 24) and install hose clamp (Figure 1, Sheet 2, Item 22).
8. Install 90-degree hose elbow (Figure 1, Sheet 2, Item 21) and hose mender fitting (Figure 1, Sheet 1, Item 19)
on top of heater (Figure 1, Sheet 2, Item 10), and install two hose clamps (Figure 1, Sheet 1, Item 20).
9. Connect hose (Figure 1, Sheet 1, Item 14) to hose mender fitting (Figure 1, Sheet 2, Item 19), and install hose
clamp (Figure 1, Sheet 2, Item 18).