TM 9-6115-729-24
0071
INSTALLATION - Continued
13. Connect hose (Figure 1, Sheet 1, Item 9) to restricted tap sleeve (Figure 1, Sheet 1, Item 6) and to OUT port
fitting on crankcase ventilation filter (Figure 1, Sheet 1, Item 10).
14. Install sensor (Figure 1, Sheet 1, Item 7) on restricted tap sleeve (Figure 1, Sheet 1, Item 6).
15. Install reducing elbow (Figure 1, Sheet 1, Item 5) on air cleaner (Figure 1, Sheet 1, Item 2) and restricted tap
sleeve (Figure 1, Sheet 1, Item 6) and install collar (Figure 1, Sheet 1, Item 4), and two clamps (Figure 1,
Sheet 1, Item 3).
16. Install air cleaner indicator (Figure 1, Sheet 1, Item 1) on air cleaner (Figure 1, Sheet 1, Item 2).
17. Close left front door and right front door.
END OF TASK
END OF WORK PACKAGE
0071-6