ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
2
TERMINATION
WIRE
BULK
NO.
FROM
TO
ENG HEAD BOLT
HTR1
M16878/3BNL-9
NOTES:
PROCEDURES:
1. Dimensions are shown in inches and
1. Cut wire (6) to 8.0 [203.2], then strip 0.5 [13] from
dimensions in [ ] are in millimeters.
ends of wire.
2. Slide insulation sleeving (2) over wire (6).
required.
3. Crimp terminal lug (1) to one end of wire (6) and
terminal lug (5) to other end of wire (6).
4. Slide insulation sleeving (2) over terminal lug (1)
and heat shrink to a tight fit.
5. Slide tube (3) over wire assembly (1, 2, 5 and 6).
Slide nipple (4) over terminal lug (5) and tube (3).
6. Install insulation sleeving (8) over tube (3) and
nipple (4) and heat shrink to a firm fit.
7. Tube (3) shall be bonded together with cable ties
(7) at 3 inch intervals.
8. Mark the appropriate wire number which will
consist of the "FROM" termination, a double-
headed arrow (↔), and the "TO" termination.