ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
TERMINATION
WIRE
WIRE
REF
BULK
WIRE
NO.
NO.
LENGTH
FROM
TO
1
R1
G2-
M16878/3BKE-9
12.75 [323.85]
2
P1-C
G2-
M16878/3BRL-9
13.75 [349.25]
3
P1-A
G2+
M16878/3BRL-9
12.0 [304.8]
4
R1
G2+
M16878/3BKE-9
12.25 [311.15]
5
P1-B
G2-FLD
M16878/3BKE-9
15.25 [387.25]
6
P1-D
G2-STA
M16878/3BKE-9
15.25 [387.25]
NOTES:
PROCEDURES:
1. Cut each wire to length indicated, then strip 0.5
1. Dimensions are shown in inches and
dimensions in [ ] are in millimeters.
[13] from ends of each wire.
2. Crimp terminal lug (9) to wire ref. no. 1. Crimp
terminal lug (10) to wire ref. no. 2. Crimp terminal
required.
lug (11) to wire ref. no. 3. Crimp terminal lug (12)
to wire ref. no. 4. Crimp quick disconnects (13) to
3. Connector (1) shall be marked "P1" on insulation
wires ref. no. 5 and 6.
sleeving (14) with 0.18 [5] minimum high
characters IAW MIL-STD-130, using rubber stamp
or stencil.
3. Position straps (4) at 3 inch intervals and at all
breakouts.
4. Mark appropriate wire number which will consist
of the `FROM' termination, a double-headed arrow
(↔), and the `TO' termination.
5. Solder leads, wires ref. no. 1 and 4 to resistor (6)
and cover solder connections with 0.75 to 1.25
[19.1 to 31.8] of insulation sleeving (7) and heat
shrink to a firm fit.
6. Insert tubing (3) into bushing (part of 2), and
cover with 1.75 to 2.25 [45.1 to 57.8] of insulation
sleeving (14) and heat shrink to a firm fit.
Figure G-13. Wiring Harness, Alternator (P/N: 95-8028) (Sheet 2 of 2)
G-23