ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
(10) Replace voltage regulator if any of above readings are not as stated.
(11) Close and secure instrument panel.
d. Removal.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Tag and disconnect electrical leads for voltage regulator (Figure 5-2) from terminals of
terminal board TB1.
(4) Remove screws, lockwashers, washers, and voltage regulator from control panel.
e. Installation.
(1) Install voltage regulator in control panel with washers, lockwashers, and screws.
(2) Connect electrical leads to terminal board TB1 and remove tags.
(3) Close and secure instrument panel.