ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
CAUTION
Use caution not to lift alternator so high that fuel line from fuel
tank to fuel filter stretches and breaks, or alternator wiring
harness is damaged.
(3) Lift alternator approximately 1-1 inches and insert block under alternator to hold
in position.
(4) Remove nuts, lockwashers, washers and capscrews securing diesel engine
resilient mount and ground strap to generator set frame. Then, remove and
discard resilient mount.
(5) Remove capscrew, washer, and lockwasher securing resilient mount to alternator
bracket. Then remove and discard resilient mount.
b.
Installation.
(1) Install new resilient mount on alternator bracket with capscrew, washer, and
lockwasher. Torque capscrew to 17 lbs-ft (23 Nm).
(2) Install new resilient mount and ground strap with alternator bracket on generator
ft (23 Nm).
(3) Remove block and lower alternator onto alternator bracket. Secure alternator to
alternator bracket with capscrews, washers, lockwashers, and nuts ensuring
alternator ground strap is installed under head of right capscrew and washers.
4.12.8. Alternator Resilient Mount Replacement. (MEP-501A)
a.
Removal.
(1) Shut down generator set.
support bracket to resilient mount.
CAUTION
Use caution not to lift alternator so high that fuel line from fuel
tank to fuel filter stretches and breaks, or alternator wiring
harness is damaged.
(3) Lift alternator approximately 1-1 inches and insert block under alternator to hold
in position.
(4) Remove nuts, lockwashers, washers and capscrews securing diesel engine
resilient mount to generator set frame. Then remove and discard resilient mount.
b.
Installation.
(1) Install new resilient mount on generator set frame with capscrews, washers,
lockwashers, and nuts. Torque nuts to 17 lbs-ft (23 Nm).
4-22