ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-101
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Tag and disconnect GROUND FAULT CIRCUIT INTERRUPTER (32, Figure 4-13) electrical
leads from TB5 and CONVENIENCE RECEPTACLE (23, Figure 4-14).
(5)
Remove nuts (30, Figure 4-13), screws (31), and GROUND FAULT CIRCUIT INTERRUPTER
(32) from DCS control panel.
(6)
Install GROUND FAULT CIRCUIT INTERRUPTER (32), screws (31), and nuts (30) on DCS
control panel.
(7)
Connect GROUND FAULT CIRCUIT INTERRUPTER (32) electrical leads to CONVENIENCE
RECEPTACLE (23, Figure 4-14) and TB5. Refer to Schematic FO-1. Remove tags.
(8)
Install DCS control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.