ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-99
(7)
Position tab washer (25) and BATTLE SHORT switch (24) on DCS control panel.
(8)
Secure BATTLE SHORT switch (24) to DCS control panel with cover (23), toothed washer (22),
and jamnut (21).
(9)
Connect electrical leads to BATTLE SHORT switch (24), and remove tags.
(10) Raise and secure DCS control panel with two fasteners.
(11) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.14 EMERGENCY STOP Switch S17.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Release DCS control panel by turning two fasteners, and lower DCS control panel slowly.
(3)
Inspect EMERGENCY STOP switch (29, Figure 4-13) for loose connections and mounting
hardware, and other damage.
(4)
Raise and secure DCS control panel with two fasteners.
b. Testing.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Release DCS control panel by turning two fasteners, and lower DCS control panel slowly.
(4)
Tag and disconnect electrical leads from EMERGENCY STOP switch (29, Figure 4-13).
(5)
Ensure EMERGENCY STOP switch (29) is in normal (out) position.
(6)
Set multimeter for ohms, and connect across EMERGENCY STOP switch (29) terminals.
Multimeter should indicate continuity.
(7)
Push EMERGENCY STOP switch (29) to (in) position. Multimeter should indicate no continuity.
(8)
If indications are not as above, replace EMERGENCY STOP switch (29).
(9)
Connect electrical leads to EMERGENCY STOP switch (29), and remove tags.
(10) Raise and secure DCS control panel with two fasteners.
(11) Connect negative battery cable to battery, and close BATTERY ACCESS door.