ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-162
(4)
Start generator set, paragraph 2.11.1. Allow unit to reach operating temperature, and check for
leaks.
(5)
Add coolant/antifreeze to overflow bottle as required.
(6)
Close engine compartment access doors.
(7)
Shut down generator set.
4.10.7 Radiator.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open engine compartment access doors (Figures 1-2 and 1-3).
(3)
Remove top housing section, paragraph 4.7.3.
__________
WARNING
Cooling system operates at high temperature and pressure. Contact with high
pressure steam and/or liquids can result in burns and scalding. Shut down
generator set, and allow system to cool before performing checks, services, and
maintenance. Failure to comply can cause injury to personnel.
__________
WARNING
DC voltages are present at the generator set electrical components even when
the generator set is shut down. Avoid shorting any positive with a ground
negative. Failure to comply can cause injury or death.
(4)
Slowly remove radiator cap (1, Figure 4-22) from filler neck (2).
(5)
Remove fan guards, paragraph 4.10.3.
(6)
Open coolant drain valve (33), and drain coolant/antifreeze into suitable container.
(7)
Remove filler hose and panel, paragraph 4.10.2.
(8)
Remove upper coolant hoses, paragraph 4.10.4.
(9)
Remove lower coolant hose, paragraph 4.10.5.
(10) Remove bolts (16), lockwashers (17), and washers (18), and allow shroud (19) to rest on fan (40).
(11) Remove nuts (20), lockwashers (21), bolts (22), washers (23), and support tie-rods (24) from
bracket on engine.
(12) Remove bolts (25), lockwashers (26), support tie-rods (24), and spacers (27) from radiator (32).