ARMY TM 9-6115-670-14&P
5-68
g. Remove six nuts with captive washers (8, Figure 5-12) (JTACS) securing relay board (6) to
vibration mounts (3), or six screws, flat and lock washers, vibration mounts (3) and hex nuts
(SICPS and WIN-T), securing relay board (6) to relay box.
h. Remove three bolts and lock washers (4, Figure 5-17) (JTACS), or three bolts, flat and lock
washers (SICPS and WIN-T) and regulator box (2). Tag and remove electrical leads and
ground wire.
i. Remove two bolts (7, Figure 5-13) (JTACS) and lock washers (6), or three bolts (SICPS and
WIN-T), flat and lock washers, and regulator box (1).
j. Remove eight bolts and lock washers (10, Figure 5-18), two generator air deflectors (9), and
two generator grills (8).
k. Secure lifting device to lifting eyes (14 and 15) on generator.
l. Reach inside generator air vents and remove six bolts and lock washers (7) securing generator
to flywheel adapter (13).
m. On generator exterior, remove four socket head screws and lock washers (16) (two on top and
two on bottom) securing generator coupling (18) to bell housing (17).
n. Reach inside generator air vents and remove four nuts and lock washers (11) from four studs
(12) (two on each side of APU) securing generator coupling (18) to bell housing (17).
o. Remove hex-head screws, lock washers and spacers (21) securing generator (19) to generator
mount (20).
NOTE
There are electrical leads and a ground wire
attached to the generator housing with one set of
hardware in the regulator box.