ARMY TM 9-6115-670-14&P
4-133
4.52. CONTACTOR MOUNTING PLATE.
This task covers:
a. Remove
b. Install
INITIAL SETUP
Tools
General Mechanic's Tool Kit
(Item 1, Appendix B)
Equipment Conditions
MASTER ON-OFF switch on APU control unit set to
OFF.
Materials/Parts
Contactor Mounting Plate
Strap, Tie down, Elect
(Item 22, Appendix F)
REMOVE
a. Refer to Figure FO-1 (SICPS/WIN-T) or F0-7 (JTACS) and move electrical leads from main AC
contactor.
(1)
Tag and remove leads from contactor terminals L1, L2, and L3 by loosening three dual
purpose screws.
(2)
Tag and remove leads from contactor terminals A1 and A2 by loosening two dual purpose
screws.
b. Refer to Figure FO-1 (SICPS/WIN-T) or F0-7 (JTACS) and move electrical leads from overload
relay.
(1)
Tag and remove leads from overload relay terminals T1, T2, and T3 by loosening three dual
purpose screws.
(2)
Tag and remove electrical leads from NC95 and NC96.
c. Refer to Figure FO-1 (SICPS/WIN-T) or F0-7 (JTACS) and move electrical leads from current
transformer.
WARNING
Ensure that APU DC power supply is
disconnected.
Failure to observe this warning could result in
severe injury or DEATH to personnel.
WARNING
Ensure that the APU is turned off and completely de-
energized before opening generator housing.
Failure to observe this warning could result in
severe injury or DEATH to personnel.
CAUTION
Take care not to cut wires or other APU components
when removing tiedown straps.