TM 9-6115-669-13&P
Table 2-1 Control Cabinet Assembly, Description of Controls and Indicators (continued).
Item
Number
15
16
AIR FILTER illuminated pushbutton
switch, red (HS, S17)
LOW FUEL lamp, amber (H15)
17
OIL TEMPERATURE meter, illumi-
nated (P10)
Green arc
Red arc
18
OIL PRESSURE meter, illuminated,
0-5 bar (P9)
19
20
READY TO START IF HEATING IS
ON lamp, green (H102)
HEATING FAILURE lamp, red
(H103)
21
22
HEATING ON illuminated pushbut-
ton switch, green (S102, H101)
HEATING OFF pushbutton switch
(S101)
23
FUEL LEVEL meter 0 - 1/1, illumi-
nated (P11)
24
HOURMETER meter (P8)
25
BATTLE SHORT switch (S21)
26
BATTLE SHORT lamp, amber (H17)
27
FREQUENCY ADJUST potentiome-
ter, 10 turn (R4)
Description
Set between 4 and 5
Function
H5 lights up when the air filter is dirty;
S17 cancels the fault message
Lights up when fuel level in fuel tank has
dropped to minimum tank level
Indicates engine oil temperature:
Operating temperature range
Overtemperature range
Indicates engine oil pressure (>4 bar during
operation)
Lights up when engine preheat time has
elapsed and engine can be started
Lights up in the event of a heating system
failure
Turns heating system on;
H101 lights up when heating system is on
Shuts heating system off;
H101 goes out when heating system is off
Indicates level in fuel tank
Activated when diesel engine is operating
Shuts off safety and monitoring functions
Lights up when safety and monitoring func-
tions are off
Adjusts generator frequency:
For rated frequency indicated on FRE-
QUENCY meter (14)
2 - 4