TM 9-6115-669-13&P
RECEPTACLE J12 AND VARISTOR R11
a.
Install receptacle (70,71, figure 5-21) with nut (72). Tighten nut (72).
b.
Install cables and cable of resistor R11(24, figure 5-20) on receptacle.
c.
Install cable (30) of resistor R11(24) on grounding stud using washer (21), serrated lock
washer (20) and nut (19). Refer to figure 6-23.
RECEPTACLE J20 AND VARISTORS R7, R8
a.
Install receptacle (44,45, figure 5-21) and gasket on connection panel (46) using screws (42),
washers (43), washers (47), serrated lock washers (48) and nuts (49). Tighten nuts (49).
b.
Install cables and cable of resistor R7 (25, figure 5-20) and cable of resistor R8 (26) to pin
J20-A of receptacle (46, figure 5-21).
c.
Install cable (29) of resistor R7 (25, figure 5-20), and cable (29) of R8 (26) on grounding stud
using washer (21), serrated lock washer (20) and nut (19). Refer to figure 5-23.
CONNECTION PANEL
a.
Install protective cover (12, figure 5-20) with plastic cap nuts (11), into spacers (10).
b.
Install panel (4) using washers (15), serrated lock washers (14), and screws (13).
c.
Install four screws (S), eight serrated lock washers (6,8) and rubber flap (7) into four spacers
(9) to panel (4).
d. Remove stanchion.
e.
Stow prop (3), close access door (2) and secure.
f.
Install stanchion by PDU (1).
5 - 5 8