TM 9-6115-669-13&P
INSTALLATION
RECEPTACLE J1 TO J4
a.
Install receptacle (22,23, figure 5-21), gasket (19) and cable on connection panel using screw
(25), washer (24), nut (16), serrated lock washer (17), and washer (18).
b.
Install three short power cables to contactor K3 to K6 in the order in which they were
removed. Refer to paragraph 5.10.
c.
Install the long power cable (11) to appropriate bus bar using screw (8), serratedlock washer
(9) and washer (10). Tighten screw (8).
d
Insert small pins (20) in receptacle (22). Refer to figure 6-22.
e.
Install grounding cable (15) using nut (12), serrated lock washer (13), and washer (14).
Tighten nut (12).
RECEPTACLE J5
a.
Install receptacle (28,29) and gasket (30) on connection panel using screw (26), washer (27,
31), serrated lock washer (32) and nut (33).
b.
Install heat shrink insulation prior to soldering all cables to receptacle (29).
c.
Solder cables to receptacle (29). Refer to figure 6-22 and table 6-4.
RECEPTACLE J6 AND VARISTORS R12, R13
a.
Install receptacle (36,37) and gasket (38) on connection panel using nut (41), serrated lock
washer (40), washer (39,35) and screw (34). Tighten screw (34).
b.
Install cables and the cable of resistor R12 (22, figure 5-20) in pin J6-R1 and the cable of
resistor R13 (23) in pin J6-S2 of receptacle (37, figure 6-21) respectively Refer to figure 6-23.
c.
Install cable of resistor R12 (28, figure 5-20), and cable of resistor R13 (29) on grounding stud
using washer (18), serrated lock washer (17) and nut (16). Tighten nut (16).
RECEPTACLE J7
a.
Install receptacle (52,53, figure 5-21), gasket (64) and fiber insulator (60) with four nuts,(59),
screws (50), washers (51,57), and serrated lock washers (68). Tighten nuts (69).
b.
Install receptacle contacts (61), ring (66) and secure with nut (55). Refer to figure 5-23.
c.
Solder cables to receptacle contacts (61).
RECEPTACLE J11 AND VARISTOR R14
a.
Install receptacle (60,66) using two screws (65), washers (67), serrated lock washers (68) and
nuts (69). Tighten nuts (69).
b.
Install cover (63) with gasket (64) and screw (62).
c.
Install varistor R14 (27, figure 5-20) and cables. Refer to figure 5-23.
5 - 5 7