TM 9-6115-669-13&P
e.
Remove nut (16, figure 5-20), serrated lock washer (17), washer (18), and cable (28) of
resistors R12 (22) and cable (28) of resistor R13 (23) from grounding stud.
RECEPTACLE J7
a.
Record labeling and position of cables on receptacle contacts (61, figure 21). Unsolder and
remove cables.
b .
Remove nut (55), ring (56) and receptacle contacts (61).
c.
&move four nuts (59), screws (50), washers (51), serrated lock washers (68) and washers (67).
d.
Remove the receptacle (52,53) and gasket (54) from outside of connection panel and fiber
insulator (60) from inside of connection panel.
RECEPTACLE J11 AND VARISTOR R14
a.
Record labeling and position of cables on receptacle (66) and remove cables.
b.
Remove one end of varistor R14 (27, figure 5-20) noting position (other end is 31).
c.
Remove screw (62, figure 5-21), cover (63) and gasket (64).
d.
Remove screws (65), washer (67), serrated lock washers (68), nuts (69), and receptacle (66).
RECEPTACLE J12 AND VARISTOR R11
a.
Loosen screw on receptacle (70) and remove cable of resistor R11 (24, figure 5-20) and
remaining cable.
b.
Remove nut (19), serrated lock washer (20), washer (21), and cable of resistor R11(30) from
grounding stud.
c.
Remove nut (72, figure 5-21), receptacle (70) and gasket (71).
5-55