TM 9-6115-664-13&P
4-23. REMOTE CONTROL CONNECTOR MAINTENANCE (LOCAL CONTROL PANEL)
C. INSPECTION.
1.
Inspect remote control connector for corrosion or other obvious damage. Inspect connector for damage and
evidence of electrical short. Check for bent, broken or missing pins.
2.
Inspect electrical wiring for cuts, abrasions, and bare wire. Inspect wire insulation for damage.
3.
Inspect wiring connector (11) for bent, broken, or missing electrical contactors. Inspect circuit card connector for
damage.
D.
INSTALLATION.
1.
Apply silicon adhesive to rear of connector (7, Figure 4-13) where connector mates to front panel (1).
2.
Install remote control connector (7) onto front panel (1) using four screws (8) and locknuts (9). Chain (10) is secured
to front panel by lower right hand screw (9).
3.
Install receptacle cap (6) onto remote control connector (7).
4.
Mate enclosure (2) to front panel (1). Connect electrical wiring connector (11) to circuit board assembly. Secure front
panel to enclosure using five screws (3), lockwashers (4), and washers (5).
5.
Install control panel assembly (Para. 4-20).
4-61