ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARINE CORPS TM 09244A/09245A-24/2
2-21.3
a.
b.
c.
d.
e.
f.
2-21.4
a.
b.
c.
d.
e.
f.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Release control panel by turning two fasteners and lower control panel slowly.
Tag and disconnect electrical leads to light receptacles (10, FIGURE 2-11).
Remove lamp holders (6), nuts (8), Iockwashers (9), and light receptacles (10) from control panel.
If necessary, remove lamps (7) from lamp holders (6).
Installation.
Install press to test light receptacles (10, FIGURE 2-11) in control panel with Iockwashers (9) and nuts (8).
If removed, install lamps (7) in lamp holders (6).
Install lamp holders (6) on light receptacles (10).
Connect electrical leads and remove tags.
Raise and secure control panel.
Connect negative battery cable and close battery access door.
2-22 SYNCHRONIZING LIGHTS.
2-22.1 Inspection.
Inspect synchronizing lights for cracks, corrosion, evidence of shorting, and other damage.
2-22.2
a.
b.
c.
d.
e.
f.
g.
2-22.3
a.
b.
c.
d.
e.
f.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Release control panel by turning two fasteners and lower control panel slowly.
Tag and disconnect synchronizing lights (13, FIGURE 2-11) electrical connections.
Remove nuts (11) and washers (12).
Remove synchronizing lights (13) from control panel.
Unscrew lenses (14) and remove lamps (15) from light receptacles (13).
Installation.
Insert synchronizing lights (13, FIGURE 2-11) into control panel.
Install washers (12) and nuts (11).
Connect electrical leads and remove tags.
Raise and secure control panel.
Install lamps (15) and screw lenses (14) on light receptacles (13).
Connect negative battery cable. Close battery access door.
2-50