2-84 COOLANT RECOVERY SYSTEM.
2-84.1
a.
b.
c.
d.
284.2
a.
b.
c.
d.
e.
f.
g.
2-84.3
a.
b.
c.
d.
e.
f.
2-118
Inspection.
Shut down generator set.
Open right side engine access doors.
Inspect coolant recovery system components for cracks, holes, or other damage.
Close right side engine access doors.
Removal.
Shut down generator set.
Open right side engine access doors.
WARNING
Coolant can get very hot. Allow system to cool down before performing mainte-
nance. Failure to follow these instructions could result in severe burns and inju-
ries.
Loosen clamp (1, FIGURE 2-25) and disconnect hose (2) from overflow bottle (5) and drain coolant into suit-
able container.
Loosen clamp (3) and disconnect hose (4) from overflow bottle (5).
Remove overflow bottle (5) from wire holder (10).
Remove bolts (6), nuts (7), Iockwashers (8), flatwashers (9), and wire holder(10)from mount(14).
Remove bolts (11), Iockwashers (12), clamp (13), and mount (14) from engine.
Installation.
Install mount (14, FIGURE 2-25) and clamp (13) on engine with bolts (11) and Iockwashers (12).
Install wire holder (10) on mount(14) with bolts (6), flatwashers (9), Iockwashers (8), and nuts (7).
Install coolant overflow bottle (5) in holder (10) and connect hoses (2) and (4) with clamps (1) and (3).
Fill overflow bottle (5) with coolant to the COLD level. Refer to TABLE 21 for proper coolant.
Start generator set, check for leaks, and run until normal operating temperature is reached.
Add coolant to HOT level of overflow bottle (5) and close right side engine access doors.