ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
d.
e.
f..
WARNING
Ensure proper lifting techniques are used when lifting batteries. Failure to observe this
warning could result in personal injury.
Remove nuts (9), washers (10), lockwashers (14), clamps (11), and retaining bar (12).
Remove batteries (13).
Inspection.
Inspect batteries for cracked cases; broken, burned or corroded posts; missing parts; and other damage.
Install batteries, paragraph 2-12-5.
Service.
f.
g.
2-12-3
a.
Remove batteries, paragraph 2-12-2.
b.
c.
2-12-4
a.
b.
c.
2-12-5
a.
b.
c.
Remove terminal covers (2, FIGURE 2-3).
Clean cable terminal lugs and battery posts.
Install terminal covers (2) on batteries (13).
Installation.
Position batteries (13, FlGURE 2-3) in generator set. Ensure that batteries are serviced and fully charged.
Apply general purpose grease (Item 10, Appendix C) to battery posts and cable terminal lugs (1), (6), (7), and
(8). (F) Apply petrolatum or equal.
Install clamps (11) and retaining bar (12) with lockwashers (14), washers (10), and nuts (9).
WARNING
Connect negative battery cable terminal lug (1) last when installing battery cables. Fail-
ure to follow this procedure could result in sparks which can ignite volatile battery gases.
Connect positive cable terminal lug (8).
Position interconnect battery cable and connect terminal lugs (6) and (7).
Connect negative battery cable terminal lug (1) and close battery compartment access door.
2-13
NATO SLAVE RECEPTACLE.
2-13-1 Inspection.
a.
Shut down generator set.
b.
Open battery access door.
c.
Inspect NATO slave receptacle for loose connections, corrosion, missing hardware, and other damage.
d.
Close battery access door.
2-32 Change 1