e.
Open radiator drain valve (28) and drain coolant/antifreeze into suitable container to a level
below radiator filler hose (3) connection at radiator.
f.
Loosen clamps (2). Remove radiator filler hose (3) and clamps (2)
g.
Loosen clamp (4) and disconnect overflow hose (5) from radiator filler neck (9).
h.
Remove radiator fill panel (6) and filler neck (9) from generator set.
i.
Remove bolts (7), nuts (8), cap (1), and radiator filler neck (9) from radiator fill panel (6).
2-77-2
lnspection and Cleaning.
a.
Shut down generator set.
b.
Remove radiator filler hose and panel, paragraph 2-77-1.
c.
Inspect radiator filler hose (3, FIGURE 2-23) for cracks, holes, and rotting.
d.
Inspect filler panel (6), filler neck (9), and cap (1) for cracks, excessive corrosion, and other
damage
e.
Clean light corrosion from filler hose attaching points with fine grit abrasive paper (Item 16,
Appendix C).
f.
Replace damaged parts.
g.
Install radiator filler hose and panel, paragraph 2-77-3.
2-77-3
Installation.
a.
Install radiator filler neck (9, FIGURE 2-23) and cap (1) on radiator fill panel (6) with bolts (7)
and nuts (8).
b.
Position radiator fill panel (6) and filler neck (9) in generator set and attach overflow hose (5)
with clamp (4).
c.
Install radiator filler hose (3) on filler neck (9) and radiator (31) with clamps (2).
d.
Install generator housing top panel, paragraph 2-16-4.
e.
Close radiator drain valve (28) and add coolant/antifreeze to proper level, paragraph 2-1-2-2.
NOTE
If replacing radiator cap solder tab to radiator cap as shown in FIGURE 2-22.
f.
Install radiator cap (1).
g.
Start generator set. Allow unit to reach operating temperature and check for leaks.
Change 1