MARINE CORPS TM 09249A/09246A-10/1
Table 2-3. Operator Preventive Maintenance Checks and Services - Continued
Item
No.
17
18
19
Interval
B
D
A
B - BEFORE
Item to
be inspected
Batteries
Battery Cables
Output Box
Assembly
D - DURING
A - A F T ER
Procedures
Check for and have
repaired or adjusted
as necessary
Battery acid can cause burns to
unprotected skin.
Batteries give off flammable gas. Do
not smoke or use open flame when
performing maintenance. Flames and
explosion could result in personal injury
or death.
Check electrolyte level.
Inspect cables and connectors for
corrosion, loose, damaged or missing
parts.
High voltage is produced when this
generator set is in operation. Improper
operation could result in personal injury
or death.
Check for loose or damaged wiring or
cables.
Check output terminals for damaged or
missing hardware.
Equipment is
not ready/
available if
Cables are loose,
damaged or missing.
Loose or damaged
wiring or cables.
Damaged or missing
hardware.