Item
No.
B
5
6
7
ARMY TM 9-6115-644-10
AIR FORCE TO 35C2-3-446-11
MARINE CORPS TM 09249A/09246A-10/1
Table 2-3. Operator Preventive Maintenance Checks and Services - Continued
B - BEFORE
D - DURING
A - A F T ER
Interval
D
A
Item to
be inspected
ENGINE
COMPARTMENT
Engine Assembly
Fuel System
Fuel Filter/ Water
Separator
Procedures
Check for and have
repaired or adjusted
as necessary
With any access door open, the noise
level of this generator set when
operating could cause hearing damage.
Hearing protection must be worn when
working near the generator set while
running.
The fuels in this generator set are highly
explosive. DO NOT smoke or use open
flame when performing maintenance.
Flames and explosion can occur
resulting in severe personal injury or
death.
Check for loose damaged or missing
hardware.
Inspect fuel system for leaks, damaged,
loose or missing parts.
Inspect fuel filter/ water separator for
leaks, proper mounting, cracks, damage,
or missing parts.
Drain water from fuel filter/ water
separator.
Equipment is
not read y/
available if:
Any fuel leaks,
damaged, loose or
missing parts.
Any fuel leaks.
Fuel filter/ water
separator not
drained.
Change 1 2-11