ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
2.13.2.
Removal.
a. Shut down generator set.
b. Open battery access door and disconnect negative battery cable.
c. Open left side engine access door and tag and disconnect battery and slave receptacle cables from slave recep-
tacle (7, FIGURE 2-4) by removing bolts(1) and Iockwashers (2).
d. Remove bolts (5), nuts (6), and NATO slave receptacle (7) from generator set housing.
e. Remove nut (8), bolt (9), and cover (10) from generator set.
2.13.3.
Installation.
a. Insert NATO slave receptacle (7, FIGURE 2-4) into left side lower door sill.
b. Secure receptacle (7) with bolts (5) and nuts (6).
c. Connect slave receptacle and battery cables to slave receptacle (7) with bolts (1) and Iockwashers (2). Remove
tags.
d. Install cover (10) on generator set with bolt (9) and nut (8).
e. Connect negative battery cable. Close battery access door and engine access door.
Section IX. MAINTENANCE OF HOUSING
2.14. ACCESS DOORS.
NOTE
This procedure is written for the left engine access door, but is typical
for all access doors, hinges, latches, and data plates.
N O TE
When removing and installing battery access door, note position of
spacers for door hold open mechanism.
2.14.1.
Removal.
a.
b.
c.
d.
e.
f.
g.
h.
Shut down generator set.
Open left side engine access door.
Remove nuts (1, FIGURE 2-5), Iockwashers (2), bolts (3), washers (4), and hinges (5).
Remove left side engine access door (6) from generator set.
Remove assembled nuts (7), bolts (8), and document box (9).
Remove assembled nuts (10), bolts (11), upper air baffle (12), and lower air baffle (13) from engine access door
(6).
Remove assembled nuts (14) and bolts (15) to separate air baffles(12) and (1 3).
Remove assembled nuts (16), bolts (17), bracket (18), and holding rod (19) from engine access door (6).
2-33