ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
NOTES:
1.
Dimensions shown are in inches.
2.
Refer to TM 9-6115-643-24P for materials required.
PROCEDURES:
1.
Strip 0.125 inch of insulation from end of each switch (1) lead.
2.
Crimp pin (2) on end of each lead.
3.
Insert pins into housing (3) with lead A in position 1, lead B in position 2, lead C in position 3, and lead D in position
4.
4.
Mark P12 on strap (4) and install in position shown.
FIGURE D-17. Switch Assembly, Fuel Level (P/N: 88-22547)
D-17