ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
2-65.3
a.
b.
c.
d.
e.
f.
Install muffler wrap (11, FIGURE 2-18) on muffler (5) with safety wire (10) in a criss-crossing pattern.
Install gasket (9), exhaust seal (6), retaining plate (7), exhaust seal spring (8), and muffler (5) at exhaust man-
ifold with Iockwashers (4) and bolts (3).
Secure other end of muffler (5) with Iockwashers (2) and bolts (1).
Connect negative battery cable.
Start generator set and check for exhaust leaks.
Shut down generator set and close engine access doors.
2-66 AIR RESTRICTION INDICATOR.
2-66.1 Inspection.
a.
Shut down generator set.
b. Open right side engine access door.
c.
Inspect air restriction indicator (1, FIGURE 2-19) for cracks, stripped threads, or other obvious damage.
2-66.2 Removal.
a.
Shut down generator set.
b. Open right side engine access door.
c.
Unscrew and remove air restriction indicator (1, FIGURE 2-19) from air cleaner housing (7).
2-66.3 Installation.
a.
Install air restriction indicator (1, FIGURE 2-19) on air cleaner housing (7).
b. Close access door.
2-67 AIR CLEANER ASSEMBLY.
2-67.1
a.
b.
c.
d.
e.
f.
g.
2-67.2
a.
b.
c.
d.
e.
f.
Removal.
Shut down generator set.
Open both engine access doors and disconnect negative battery cable.
Loosen clamps (2, FIGURE 2-19) and remove hose (3) from air cleaner housing (7) and engine intake.
Loosen clamp (4) and remove hose (5) from air cleaner housing (7).
Open clamps (6) and remove air cleaner assembly from generator set.
Remove air cleaner element, paragraph 2-68.1.
Do not permit nuts or bolts on clamps to drop into generator set.
Remove control box top panel, paragraph 2-16.1 to remove bolts (8), washers (9), Iockwashers (10), nuts (11),
and clamps (6) from generator set.
Inspection and Service.
Shut down generator set.
Open left side engine access door and disconnect negative battery cable.
Remove top housing panel, paragraph 2-17.1.
Inspect air cleaner housing and mounting clamps for dents, cracks, corrosion, and other damage.
Service by replacing air cleaner element.
Install top housing panel, paragraph 2-17.4.
2-93
Installation.