ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-455-12
MARINE CORPS TM 09247A/09248A-24/2
2-64.4 Installation.
a.
Install mounting bracket (18, FIGURE 2-16) with screws (17) in output box assembly.
When installing the voltage reconnection switch, use extreme care not to drop
the attaching hardware down on the generator unit. Serious damage to equip-
ment could occur.
b. Install voltage reconnection switch (16) in output box assembly and secure with screws (11) and (14), washers
(12), and nuts (13) and (15).
c.
Connect electrical leads to voltage reconnection switch as tagged and remove tags.
d. Install control box assembly, paragraph 2-21.4.
e. Connect negative battery cable and close access door.
SECTION XII. MAINTENANCE OF AIR INTAKE AND EXHAUST SYSTEM
2-65 MUFFLER.
2-65.1 Removal.
a.
Shut down generator set.
b. Open both engine access doors and disconnect negative battery cable.
WARNING
The exhaust system can get very hot. Allow system to cool before performing
maintenance. Failure to follow these instructions could result in severe burns
and injuries.
c.
Remove bolts (1, FIGURE 2-18) and lockwashers (2) at intake manifold.
d. Remove bolts (3), lockwashers (4), muffler (5), exhaust seal (6), retaining plate (7), and exhaust seal spring
(8) from generator set.
e.
Remove gasket (9) from exhaust manifold.
f.
Unlace safety wire (10) and remove wrap (11) from muffler (5).
2-65.2 Cleaning and Inspection.
.
a.
Remove muffler, paragraph 2-65.1.
WARNING
Dry cleaning solvent is flammable and toxic to eyes, skin, and respiratory tract.
Skin/eye protection required. Avoid repeated/prolonged contact. Good general
ventilation is normally adequate.
b. Clean muffler with stiff bristle brush and dry cleaning solvent (item 19, Appendix C).
c.
Inspect muffler for dents, cracks, excessive corrosion, clogging, and other damage.
d. Inspect wrap for tears, broken or missing cap stands, and other damage.
e.
Replace damaged parts.
f.
Install muffler, paragraph 2-65.3.
2-92