ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
2-83-2. Inspection
a.
Shut down generator set.
b. Remove fuel tank, paragraph 2-83-1.
c.
Inspect fuel tank for leaks and cracks.
d.
Install fuel tank, paragraph 2-63-3.
2-83-3. Installation.
a.
Install fuel level sender, paragraph 2-76-4, fuel float switch, paragraph 2-77-4, and fuel pickup paragraph
2-78-3 in fuel tank (33, Figure 2-21).
b. Install bushings (38) and (42), washers (37) and (41), and fittings (36) and (40) in fuel tank (33).
c.
Install adapter (39) in fuel tank fitting (40).
d.
Install fittings (35) and (34) in fuel tank fitting (36).
e.
Install fuel tank (33) in generator set.
f.
Install fuel tank drain valve, paragraph 2-82-2.
g.
Install front housing section (except front housing panel), paragraph 2-19-4.
h.
Service fuel tank with diesel fuel. Refer to Table 2-2 for recommended fuel.
i.
Connect negative battery cable.
j.
Start generator set and check for leaks and proper operation.
k.
Shut down generator set and install front housing panel, paragraph 2-18-4.
2-84. AUXILIARY FUEL PUMP.
2-84-1. Inspection
a.
Shut down generator set.
b.
Remove front housing panel, paragraph 2-16-1.
c.
Check auxiliary fuel pump (54, Figure 2-21) for leaks, cracks, missing hardware, and loose connections.
d.
Install front housing panel, paragraph 2-18-4.
2-84-2. Testing.
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
2-116
Remove front housing panel, paragraph 2-16-1.
Connect generator set to auxiliary fuel supply at fitting (49, Figure 2-21).
NOTE
Ensure auxiliary fuel supply is level with or above auxiliary fuel pump inlet.
Disconnect auxiliary fuel pump outlet tube (50) at fuel tank fitting (35) and place end in measuring container.
Connect negative battery cable.
Move generator set MASTER SWITCH to PRIME & RUN AUX FUEL position for 1 minute and return MASTER
SWITCH to OFF position.
Measuring container should have collected at least 32 oz (0.95 liter) of fuel.
Replace auxiliary fuel pump if delivery amount is other than above.
Connect auxiliary fuel pump outlet tube (50) at fuel tank fitting (35).
Disconnect generator set from auxiliary fuel supply.
Disconnect negative battery cable.