ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
2-55-2. Inspection.
Inspect control panel frame (12, Figure 2-15) for dents, cracks, loose paint, and corrosion.
2-55-3. Repair.
Wear a protective mask and gloves when sanding CARC painted surfaces. CARC
paint dust is a health hazard and could cause personal injury if warning is not
followed.
a.
Repair all dents and cracks, and remove all loose paint.
b. Remove light corrosion with fine grit abrasive paper (Item 15, Appendix C).
c.
Repaint surface in accordance with TM 430139. (F) Refer to applicable directives.
2-55-4. Installation.
a.
Install control panel frame (12. Figure 2-15) on control box assembly with bolts (8) and (10), and nuts (9) and
(11).
b. Install malfunction indicator panel, paragraph 2-24-4.
c.
Install ground fault circuit interrupter, paragraph 2-23-4.
d. Install convenience receptacle, paragraph 2-22-4, and diagnostic connector, paragraph 2-36-3.
e.
Install control panel, paragraph 2-54-4 and control box top panel, paragraph 2-16-4.
f.
Connect negative battery cable and close access door.
2-86