ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
2-50-2. Testing.
a.
Shut down generator set.
b. Open left side engine access door and disconnect negative battery cable.
c.
Release control panel by turning two fasteners and lower control panel slowly.
d. Place BATTLE SHORT switch in ON position.
NOTE
Refer to Wiring Diagram FO2 for terminal positions and isolate switch from circuit.
e.
Using multimeter, check for continuity between terminals: 2 and 3; 5 and 6; 8 and 9; and 11 and 12.
f.
Place switch in OFF position.
g.
Check for continuity between terminals: 1 and 2; 4 and 5; 7 and 8; and 10 and 11.
h.
Replace switch if any open circuit is indicated.
i.
Raise and secure control panel.
j.
Connect negative battery cable. Close access door.
2-50-3. Removal.
a.
Shut down generator set.
b. Open left side engine access door and disconnect negative battery cable.
c.
Release control panel by turning two fasteners and lower control panel slowly.
d. Tag and disconnect BATTLE SHORT switch (54, Figure 2-14) electrical leads.
e.
Remove nut (51), washer (52), and protective cover (53).
f.
Remove BATTLE SHORT switch (54) from control panel.
g. Remove tab washer (55) from switch stem.
2-50-4. Installation.
a.
Install tab washer (55, Figure 2-14) on BATTLE SHORT switch (54).
b.
Insert BATTLE SHORT switch (54) into control panel.
c.
Install protective cover (53), washer (52), and nut (51).
d. Connect electrical leads and remove tags.
e.
Raise and secure control panel.
f.
Connect negative battery cable and close access door.
2-51. CIRCUIT INTERRUPTER SWITCH.
2-51-1. Inspection.
a. Shut down generator set.
b. Release control panel by turning two fasteners and lower control panel slowly.
c.
Inspect AC CIRCUIT INTERRUPTER switch for cracks, loose or damaged connections, corrosion, and other
damage.
d.
Raise and secure control panel.
2-81