ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
2-49. EMERGENCY STOP SWICTH.
2-49-1. Inspection.
a.
Shut down generator set.
b.
Release control panel by turning two fasteners and lower control panel slowly.
c.
Inspect EMERGENCY STOP switch for cracks, loose mounting, corrosion, and other damage.
d.
Raise and secure control panel.
2-49-2. Testing.
a.
Shut down generator set.
b. Open left side engine access door and disconnect negative battery cable.
c.
Release control panel by turning two fasteners and lower control panel slowly.
d.
With switch in normal (out) position, set multimeter for ohms and check circuit between switch
terminals. If no continuity is indicated, EMERGENCY STOP switch is defective.
e.
Push in EMERGENCY STOP switch.
f.
Check for continuity between switch terminals. Replace switch if continuity is indicated.
9.
Raise and secure control panel.
h.
Connect negative battery cable and close access door.
2-49-3. Removal.
a.
Shut down generator set.
b.
Open left side engine access door and disconnect negative battery cable.
c.
Release control panel by turning two fasteners and lower control paneI slowly.
d. Tag and disconnect EMERGENCY STOP switch (50, Figure 2-14) electrical leads.
e.
Remove nut (48) and washer (49).
f.
Remove EMERGENCY STOP switch (50) from control panel.
2-49-4. Installation.
a.
Insert EMERGENCY STOP switch (50, Figure 2-14) into control panel.
b.
Install washer (49) and nut (48).
c.
Connect electrical leads and remove tags.
d.
Raise and secure control panel.
e.
Connect negative battery cable and close access door.
2-50.
BATTLE SHORT SWICTH.
2-50-1. Inspection.
a.
Shut down generator set.
b.
Release control panel by turning two fasteners and lower control panel slowly.
c.
Inspect BATTLE SHORT switch for cracks, loose or damaged connections, corrosion, and other damage.
d.
Raise and secure control panel.
2-80