ARMY TM 9-6115-639-13
AIR FORCE TO 35C2-3-386-51
MARINE CORPS TM 10155A-13/1
4-46. MAIN ACCESS COVER MAINTENANCE
This task covers test, removal, inspection, and installation.
INITIAL SETUP
Tools:
Equipment Condition:
Tool Kit, General Mechanics Automotive
Generator set shut down (Para. 2-9)
(Item 2, App. B, Sect. III)
Personnel Required:
Two (2) personnel
A. TEST
1.
To test for water leakage, unlock main access cover latches (2, Figure 4-37) and lift cover (1) to open.
2.
Cover Power Inverter/Converter (A8) (19, Figure 1-2) with plastic.
3.
Close main access cover latches (2, Figure 4-37) and lock in place using latches.
4.
Spray water (low pressure) over cover.
5.
Wipe exterior of cover to remove water.
6.
Unlock main access cover latches (2) and lift cover (1) to open.
7.
Inspect for new signs of water.
8.
If water is present, dry the inside of the generator thoroughly and replace gaskets (Para. 4-46.D.)
B. REMOVAL.
1.
Unlock generator set main access cover latches (2, Figure 4-37).
2.
Disconnect electrical plug (22) from fan (23). Remove two wire clamps (24) by removing screws (25),
lockwashers (26), and washers (27).
3.
Release two cover supports (3) from cover (1) by removing screws (4), lockwashers (5), and washers (6).
4.
Remove cover hinges (7, 11) from cover (1) by removing four screws (12), washers (13), and locknuts
(14). Lift cover (1) off generator set and place on a clean work surface for further maintenance.
5.
Remove cover hinges (7, 11) from left side panel by removing six screws (8), washers (9), and locknuts
(10).
4-100